A. DESCRIPTION: THE TRANSMITTING SET COUNTERMEASURES (TSC),
AN/GLQ-14, IS EQUIPPED WITH A TRANSMITTER, ANTENNA ELEMENTS AND
ELECTRONIC COMPONENTS THAT ACCEPT TARGET ASSIGNMENT FROM THE
AN/TSQ-177 AND IMPLEMENT TASKINGS RECEIVED. THE AN/GLQ-14 ALSO HAS A
CHIRP SOUNDER TRANSMITTER WITH WHICH IT SOUNDS THE ATMOSPHERE WHEN
TASKED. THE AN/GLQ-14 HAS A LIMITED STAND ALONE MANUAL CAPABILITY
WHEREIN TASKING DATA CAN BE INPUT BY THE OPERATOR. THE AN/GLQ-14
CONSISTS OF SEVERAL MAJOR COMPONENTS. THE COMMUNICATION INTERFACE
(ALSO CALLED THE DIRECTOR) IS HOUSED IN A S280 SHELTER MOUNTED ON A 5
TON VEHICLE. THERE ARE ONE MINOR AND TWO MAJOR AMPLIFIER SYSTEMS.
THE MINOR AMPLIFIER SYSTEM IS HOUSED IN A S280 SHELTER WITH THE
COMMUNICATIONS INTERFACE. THE TWO MAJOR AMPLIFIER SYSTEMS ARE HOUSED
IN DUAL ISO SHELTERS MOUNTED ON A FLATBED SEMI-TRAILER. THE
AN/GLQ-14 IS EQUIPED WITH A SPECIAL PURPOSE CRANE/AUGER FOR
LOADING/UNLOADING AND INSTALLING THE ANTENNA. THE ANTENNA IS CARRIED
ON A FLATBED SEMI-TRAILOR. A THIRD FLATBED SEMI-TRAILOR IS USED TO
CARRY THE MEP-012A GENERATOR. THE POWER FOR OPERATION OF THE
AN/GLQ-14 MAY BE SUPPLIED BY WORLDWIDE COMMERCIAL POWER OR STANDARD
ARMY POWER SOURCES (GENERATORS).
B. CAPABILITIES: THE TECHNICAL CAPABILITIES OF THE SYSTEM IS
CLASSIFIED. THE AN/GLQ-14 OPERATES AS PART OF THE AN/TLQ-33
COUNTERMEASURES SYSTEM. IT IS CAPABLE OF BEING OPERATED, STORED, AND
TRANSPORTED IN HOT, BASIC, AND COLD CLIMATS, AS DEFINED IN AR 70-38.
IT WILL FUNCTION WITHOUT DEGRADATION UP TO 7,000 FEET ABOVE SEA LEVLE
AND WILL WITHSTAND AND OPERATE IN SURFACE WIND GUSTS OF UP TO 90 MPH.
C. EMPLOYMENT: EMPLOYMENT OF THE SYSTEM IS CLASSIFIED.
D. BASIS OF ISSUE: ONE PER HIGH POWER SECTION, EW COMPANY (AHFEWS).
E. POWER REQUIREMENTS: GENERATOR POWER REQUIRED IS 4160 VAC, 750KW,
3 PHASE, 60HZ FOR THE AMPLIFIER AND 208 VAC, 100KW, 3 PHASE, 60HZ FOR
THE TRANSMITTER. THE DIRECTOR REQUIRES 308V AC, 60KW, 3 PHASE, 50HZ
(SHELTER) AND 460 VAC, 60A, 3 PHASE (ECU). THESE GENERATOR POWER
REQUIREMENTS ARE SATISFIED BY ONE PU-495B/G 100KW, ONE PU-650B/G
60KW, AND ONE MEP-012A 750KW GENERATOR. COMMERCIAL POWER CAN BE
SUBSTITUTED WHERE AVAILABLE IN THE CORRECT SPECIFICATIONS.
COMMERCIAL POWER REQUIRED FOR THE AMPLIFIER IS 4160VAC, 250KKVA, 3
PHASE, 60HZ. COMMERCIAL POWER REQUIRED FOR THE TRANSMITTER IS
208VAC, 100KVA, 3 PHASE, 60HZ. COMMERCIAL POWER FOR THE DIRECTOR AT A
LINE FREQUENCY OF 50 HZ IS 380VAC, 200A, 3 PHASE. FOR A LINE
FREQUENCY OF 60HZ THE DIRECTOR REQUIREMENT IS 380VAC, 100A, 3 PHASE
(SHELTER) AND 460VAC, 60A, 3PHASE (ECU).
F. TRANSPORTATION REQUIREMENTS: THE AN/GLQ-14 IS TRANSPORTABLE BY
HIGHWAY, MARINE, OR AIR. IT IS CAPABLE OF BEING TRANSPORTED BY C-141
AIRCRAFT.
G. PERSONNEL/MAINTENANCE IMPACTS:
(1) OPERATOR: CREW OF 6: 4 98H AND 2 98K.
(2) MAINTAINERS:
(A) UNIT: MOS 31U, 33T
(B) GS/DS: MOS 35E, 35W, 44B
H. SPECIAL NOTES: THIS ITEM IS NOT APPROPRIATE FOR INCLUSION IN AR